Vector Power Supply BD051605 User Manual

VEC1028POB  
POWER ON BOARD 2 YEAR LIMITED WARRANTY PROGRAM  
This limited warranty program is the only one that applies to this product, and it sets forth all the  
responsibilities of Power on Board, regarding this product. There is no other warranty, other than those  
described herein.  
This Power on Board product is warranted, to the original purchaser only, to be free of defects in materials  
and workmanship for two years from the date of purchase without additional charge. The warranty does  
not extend to subsequent purchasers or users. Power on Board will not be responsible for any amount of  
damage in excess of the retail purchase price of the product under any circumstances. Incidental and  
consequential damages are specifically excluded from coverage under this warranty.  
Rechargeable  
This product is not intended for commercial use. This warranty does not apply to accessories or damage to  
units from misuse or incorrect connection/installation. Misuse includes wiring or connecting to improper  
polarity power sources.  
RETURN/REPAIR POLICY: Defective products, other than accessories, may be returned to Power on Board.  
Any defective product, other than accessories, that is returned to Power on Board within 30 days of the date  
of purchase will be replaced free of charge. If such a product is returned more than 30 days but less than  
two years from the purchase date, Power on Board will repair the unit or, at its option, replace it free of  
charge.  
Power Center  
Jump-Starter/Air Compressor/Inflator  
AC/DC Portable Power Supply  
If the unit is repaired, new or reconditioned, replacement parts may be used, at Power on Boards option.  
A unit may be replaced with a new or reconditioned unit of the same or comparable design. The repaired  
or replaced unit will then be warranted under the terms of the remainder of the warranty period. The  
customer is responsible for the shipping charges on all returned items after 30 days. During the warranty  
period, Power on Board will be responsible for the return shipping charges.  
LIMITATIONS: This warranty does not cover accessories, bulbs, fuses and batteries, defects resulting from  
normal wear and tear (including chips, scratches, abrasions, discoloration or fading due to usage or  
exposure to sunlight), accidents, damage during shipping to our service facility, alterations, unauthorized  
use or repair, neglect, misuse, abuse, failure to follow instructions for care and maintenance, fire, flood or  
Acts of God.  
If your problem is not covered by this warranty, call our Technical Support Department at (954) 584-4446  
or toll free at (866) 584-5504 for general repair information and charges if applicable.  
STATE LAW RIGHTS: This warranty gives you specific legal rights. Some states do not allow limitations on  
how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages,  
so the exclusions or limitations stated herein may not apply. This warranty gives the purchaser specific legal  
rights; other rights, which vary from state to state, may apply.  
TO REQUEST WARRANTY SERVICE FOR THIS PRODUCT: Contact Power on Board Technical Support by  
telephone, fax or mail. We suggest that you keep the original packaging in case you need to ship the unit.  
When returning a product, include your name, address, phone number, dated sales receipt (or copy) and  
a description of the reason for return and product serial number. After repairing or replacing the unit, we  
will make every effort to return it to you within four weeks.  
WARRANTY ACTIVATION: Please complete Warranty Activation Card and mail to Power on Board. Enter  
“VEC1028POB” as Model and “Power Center” as Product Type. All Power on Board products must be  
registered within 30 days of purchase to activate this warranty. Mail the completed registration form, along  
with a copy of the original sales receipt to:  
ATTN.: CUSTOMER SERVICE  
USER’S MANUAL  
4140 SW 30th Ave., Ft. Lauderdale, FL 33312  
• PH: 954-584-4446 • TOLL FREE: 866-584-5504 • FAX: 954-584-5556 •  
& WARRANTY INFORMATION  
IMPORTANT SAFETY INFORMATION, SAVE THESE INSTRUCTIONS  
WARRANTY IS NON-TRANSFERABLE AND NON-REFUNDABLE.  
TO REDUCE THE RISK OF INJURY, USER MUST READ AND UNDERSTAND  
THIS INSTRUCTIONAL MANUAL. THIS MANUAL CONTAINS IMPORTANT  
INFORMATION REGARDING THE OPERATION AND WARRANTY OF THIS  
PRODUCT. PLEASE RETAIN FOR FUTURE REFERENCE.  
BD051605  
4140 S.W. 30th Ave., Ft. Lauderdale, FL 33312  
Toll Free: (866) 584-5504  
© 2006 VECTOR MANUFACTURING  
MADE IN CHINA  
 
TABLE OF CONTENTS  
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
AC and DC Charging/Recharging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3  
Viewing Battery Charge Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3  
120 Volt AC Charging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
12 Volt DC Charging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
Using the Power Center as a Jump-Starter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
Using the 12 Volt Portable Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6  
Using the 120 Volt AC Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6  
Using the Emergency Area Light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7  
Using the Air Compressor/Inflator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7  
Inflating Products With a Valve Stem Using the Compressor . . . . . . . . . . . . . . . 7  
Inflating Products Without a Valve Stem Using the Compressor . . . . . . . . . . . . . 8  
Using the Inflator/Deflator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8  
Care and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9  
Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9  
Battery Replacement/Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9  
Fuse Replacement (DC Accessory Adapter) . . . . . . . . . . . . . . . . . . . . . . . . . . . 9  
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10  
INTRODUCTION  
Thank you for purchasing the VEC1028POB Power Center. Please read this  
guide carefully before use to ensure optimum performance and avoid damage to  
the unit.  
FEATURES  
• Powers 110/120 volt AC appliances  
• Powers 12 volt DC appliances  
• Jump-starts vehicle engines  
• Built-in air compressor/inflator with pressure gauge, hoses and adapters  
• Built-in 400 watt inverter  
• Includes non-spillable, maintenance-free, heavy-duty, sealed battery  
• Safe to use, transport and store  
• Reverse polarity connection warning  
• Self-stored jumper cables  
• Requires no maintenance (other than recharging) for optimum operation  
• Rechargeable with built-in AC charger  
• Unique compact design provides completely portable 12 volt DC power  
• Molded high-impact case is tough and durable  
• Built-in area light for night time roadside repairs and use in remote locations without  
utility power  
This device complies with part 15 of the FCC rules. Operation is subject to the following two  
conditions: (1) this device may not cause harmful interference, and (2) this device must accept any  
interference received, including interference that may cause undesired operation.  
This equipment has been tested and found to comply with the limits for a Class B digital device,  
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection  
against harmful interference in a residential installation. This equipment generates, uses and can  
radiate radio frequency energy and, if not installed and used in accordance with the instructions,  
may cause harmful interference to radio communications. However, there is no guarantee that  
interference will not occur in a particular installation. If equipment does cause harmful interference  
to radio or television reception, which can be determined by turning the equipment off and on, the  
user is encouraged to try to correct the interference by one or more of the following measures:  
• Reorient or relocate the receiving antenna.  
• Increase the separation between equipment and receiver.  
• Connect the equipment into an outlet on a circuit different from that to which the receiver is  
connected.  
• Consult the dealer or an experienced radio/TV technician for help.  
• Battery charge level indicators  
 
iv  
1
Front Panel  
Protective Features  
Automatic Overload — Built-in protection against overload — in the event the  
AC outlet draws more than 400 watts, power to the unit’s outlet will automatically  
shut off.  
Ground Fault Circuit Interrupter (GFCI) — The GFCI protects the unit and the  
user by sensing imbalances in a circuit caused by current leakage to the ground  
and shuts down the unit’s AC outlet to prevent electrical shock.  
BATTERY CHARGE  
BATTERY CHARGE LEVEL  
LEVEL INDICATORS  
PUSHBUTTON  
JUMP-START SAFETY  
ON/OFF SWITCH  
Overheating — Unit automatically shuts down if it exceeds a safe temperature.  
REVERSE POLARITY  
INDICATOR  
Safety Power Switch and Reverse Polarity Alarm — In the event the  
cables/clamp connections are reversed during jump-starting, an indicator lights  
and an alarm sounds BEFORE the Power Switch is turned ON.  
Low Battery — If the battery power level is too low, the AC Power Supply shuts  
down automatically.  
AREA LIGHT  
ON/OFF SWITCH  
AREA LIGHT  
Front View  
AC AND DC CHARGING/RECHARGING  
Use a common household AC extension cord for charging (cord not supplied).  
For maximum battery life, we recommend the unit be kept fully charged at all times.  
If the battery is allowed to remain in a discharged state, battery life will be shortened.  
RUBBER HANDLE  
AIR VENTS  
DC POWER SUPPLY  
PORT  
UNIT  
FRONT PANEL  
• MAKE SURE ALL SWITCHES ARE TURNED OFF DURING RECHARGING.  
• FULLY CHARGE THE UNIT USING THE 120 VOLT AC CHARGING METHOD  
AIR COMPRESSOR/  
BEFORE FIRST USE.  
INFLATOR PANEL  
JUMPER  
CABLES  
• Recharge the unit fully after each use.  
• Recharge the unit every two months when it has not been used regularly.  
Notes: Recharging the battery after each use prolongs battery life; frequent  
discharges between recharges reduces battery life.  
INFLATOR  
The Power Center also comes with a 12 Volt DC charging adapter for  
recharging the unit from a 12 volt DC accessory outlet in a vehicle.  
AC POWER  
SUPPLY PANEL  
If unit is fully discharged, it is recommended that the vehicle being used for  
recharging be left running while the unit is charged via the 12 volt DC  
method.  
Back View  
Viewing Battery Charge Status  
Press the Battery Charge Level pushbutton to display battery status. The Battery  
Charge Level Indicator LEDS will light.  
BUILT-IN  
AC CHARGER  
LEDs (from right to left):  
• One Red LED indicates a low battery charge  
• Two or three Red LEDs indicate a medium level or partially charged battery  
• Three Red and one Green LEDs indicates a full or high  
level battery charge.  
INFLATOR/DEFLATOR  
HOSE STORAGE  
JUMPER CABLE  
CLAMP TABS  
COMPARTMENT  
 
2
3
120 Volt AC Charging  
Jump-Starting Instructions  
1. Lift the AC Charger cover located on the back of  
the Power Center and connect a standard  
household extension cord to the unit. Plug the  
other end of the cord into a standard North  
American 120 volt AC wall outlet.  
2. Charge until three Red and one Green LEDs light.  
3. Once fully charged, disconnect the extension cord.  
Note: The unit cannot be overcharged using this method.  
This jump-starter is equipped with a manual safety switch that only allows jump-start  
energy to flow when proper connections are made to battery and frame.  
Connect — RED clamp first, then BLACK clamp. Disconnect — BLACK clamp first,  
then RED clamp.  
1. Turn OFF vehicle ignition and all accessories (radio, A/C, lights, cell phone, etc.).  
Place vehicle in “park” and set the emergency brake.  
2. Make sure jump-start system’s ON/OFF power switch is turned to OFF.  
3. Connect jumper cables to unit.  
4. To jump-start a NEGATIVE GROUNDED SYSTEM (NEGATIVE battery terminal  
is connected to the chassis — the most common configuration), follow steps 4a  
and 4b, then proceed to step 6.  
12 Volt DC Charging  
The 12 Volt DC recharging method will NOT recharge the unit as  
effectively as recharging from 120 volt AC. The 12 volt DC  
recharging procedure is recommended only when it is necessary,  
since frequent use of the 12 volt DC recharging procedure may  
shorten the battery system’s life.  
4a. Connect the POSITIVE (+) RED clamp to vehicle battery’s POSITIVE  
ungrounded post.  
4b. Connect the NEGATIVE (–) BLACK clamp to the vehicle chassis or engine  
block away from the battery. Do not connect the clip to carburetor, fuel lines  
or sheet-metal body parts. Connect to a heavy gauge metal part of the frame  
or engine block.  
1. Insert the gold-tipped DC Charging Adapter end plug into the  
vehicle’s 12 volt DC accessory outlet.  
2. Insert the silver-tipped end plug into the 12 volt DC accessory  
outlet on the front panel of the unit.  
3. To check the charge status of the battery during  
DC charging, disconnect the DC adapter from  
the accessory outlet and push the Battery Charge  
Level pushbutton. Observe the battery charge  
indicator.  
5. To jump-start a POSITIVE GROUNDED SYSTEM — In the rare event that the  
vehicle to be started has a POSITIVE Grounded System, POSITIVE battery  
terminal is connected to chassis, replace steps 4a and 4b above with steps 5a  
and 5b, then proceed to step 6.  
5a. Connect NEGATIVE (–) BLACK clamp to vehicle battery’s NEGATIVE  
ungrounded post.  
5b. Connect POSITIVE (+) RED clamp to the vehicle chassis or engine block  
away from the battery. Do not connect the clip to carburetor, fuel lines or  
sheet-metal body parts. Connect to a heavy gauge metal part of the frame  
or engine block.  
DO NOT TURN SAFETY SWITCH ON IF REVERSE POLARITY ALARM  
SOUNDS OR THE REVERSE POLARITY INDICATOR LIGHTS. REVERSE  
THE CLAMP CONNECTIONS.  
4. When charging is complete, remove the power  
cord.  
WARNING  
Do not recharge for more than 5 to 6 hours maximum using the  
12 volt DC method.  
USING THE POWER CENTER AS A JUMP-STARTER  
6. After making proper connections, turn safety power switch to ON.  
7. Start vehicle (do not turn key for longer than 5-6 seconds).  
8. After vehicle starts, turn the safety power switch to off, remove clamps (disconnect  
the frame or engine clamp first, followed by the battery cable). Store the cables  
on the clamp tabs on the back of the unit.  
WARNINGS  
• Before using this system to jump-start any vehicle read and  
understand all instructions, safety tips, warnings, cautions and first  
aid information provided in this manual and on the product labeling.  
Additional important information may also be provided by the  
vehicles battery system manufacturer.  
Notes: Always disconnect the engine or frame jumper clamp first; followed by  
the battery jumper clamp.  
Connect or disconnect battery leads ONLY when AC or DC charging  
If engine fails to start, leave the ignition turned off and disconnect the  
NEGATIVE (–) clamp first, then the POSITIVE (+) clamp. Try again later —  
the engine may be flooded.  
supply cords are disconnected.  
CAUTIONS  
Recharge the Power Center after each use.  
• To avoid possible damage that may shorten the units working life,  
protect this unit from direct sunlight, direct heat and moisture.  
• This system is to be used ONLY on vehicles, garden tractors and  
gasoline-powered generators with 12 volt DC battery systems.  
• This system is NOT designed to be installed as a replacement for a  
vehicle battery.  
 
4
5
USING THE 12 VOLT DC PORTABLE POWER SUPPLY  
USING THE EMERGENCY AREA LIGHT  
1. Flip open the 12 Volt DC Outlet cover on the upper  
The Area Light is controlled by an ON/OFF pushbutton. Make sure the light is turned  
right side of the unit.  
OFF when the unit is being recharged or stored.  
2. Insert the 12 volt DC plug from the appliance into the  
outlet.  
3. Turn on the appliance and operate normally.  
CAUTION  
DO NOT USE UNIT TO POWER APPLIANCES  
THAT DRAW MORE THAN 5 AMPS DC.  
USING THE AIR COMPRESSOR/INFLATOR  
The built-in 12 volt DC Air Compressor is the ultimate  
inflator for all vehicle tires, trailer tires and sports  
inflatables. The attached Air Compressor Hose with  
standard tire valve connector (chuck) and three  
12 VOLT DC  
OUTLET  
different sized nozzles are located on the front left  
panel of the unit in the compartment labeled “Air.”  
AIR COMPRESSOR  
HOSE  
USING THE 120 VOLT AC POWER SUPPLY  
The Power Center comes with:  
Each nozzle clips on the end of the standard tire  
valve connector attached to the free end of the air  
compressor hose.  
INFLATOR/DEFLATOR HOSE  
AC POWER SUPPLY  
PANEL  
1. AC ON/OFF Switch — Press switch to turn the AC  
Power Supply ON and OFF.  
The Inflator/Deflator is useful for quickly inflating and  
deflating such items as air mattresses, pool toys,  
etc. The detached Inflator/Deflator Hose connects to  
either the Inflator or Deflator port also located in the  
compartment labeled “Air” on the front left panel of  
the unit. The Inflator/Deflator Hose is stored in a  
compartment in the back of the unit.  
2. Dual 120 Volt AC Power Outlets  
AIR  
3. AC Power Supply “ON” Status Indicator — green  
LED lights when AC outlet is turned on; green LED  
flashes on and off when faulted.  
4. AC Power Ground Fault Circuit Interrupt (GFCI) —  
two three-prong outlets for 110/120 volt AC  
appliances which shut down inverter if leakage or  
ground fault current is detected.  
PANEL  
AIR  
COMPRESSOR  
HOSE  
WARNING  
The air compressor is capable of inflating  
up to 120 pounds per square inch (psi).  
To avoid overinflating, carefully follow  
instructions on articles to be inflated. Never  
exceed recommended pressures. Always  
check pressure with the pressure gauge.  
Never leave the Air Compressor/ Inflator  
unattended while in use. Bursting articles  
can cause serious injury.  
5. Internal protective circuits including:  
• Overload and over-temperature shutdown (activated if AC output exceeds 400  
watts or the unit overheats)  
• AC short-circuit shutdown  
• Low voltage shutdown  
• A new cooling technology that more efficiently cools the power transistors,  
PRESSURE GAUGE  
dramatically increasing reliability and product life.  
AC Power Supply Controls and Indicators  
CAUTION  
The illustration above details the AC Power Supply Panel. The ON/OFF switch turns  
the AC power circuitry on and off. The ON/OFF switch can also be used to reset the  
AC power after shutdown due to overvoltage, overload or over-temperature  
condition. The “ON” status indicator lights when the AC power supply is on.  
Do not operate the Air Compressor/Inflator  
continuously for extended periods of time  
(approx. 15 minutes, depending on the  
ambient temperature), as it may overheat.  
In such event, the Air Compressor will shut  
down and can be restarted after a cooling  
period of approximately 15 minutes.  
AC Power Supply Operation  
1. Turn power switch to ON (the power indicator lights).  
2. Plug in appliance and operate as usual.  
Note: The AC power supply shuts down automatically when the battery voltage level  
is too low. If the green LED flashes, a faulty condition such as an overload,  
overheating or short circuiting has occurred. Turn the AC Power Supply OFF and  
unplug the appliance. Wait a few minutes, then turn power back ON.  
Inflating Products With a Valve Stem Using the Compressor  
1. Place the standard connector (chuck) of the Air Compressor Hose on the valve  
stem.  
2. Push connector toward valve stem and close thumb latch.  
Note: Make sure connector is pushed onto valve stem as far as possible  
before closing thumb latch.  
3. Slide Air Compressor/Inflator Switch to COMPRESSOR.  
 
6
7
4. Monitor the pressure gauge. When desired pressure is reached, slide the Air  
Compressor/Inflator Switch to OFF; open thumb latch and remove connector  
from valve stem.  
Deflating  
1. Open the valve on your product completely to release air.  
2. Fasten the Inflator/Deflator Hose (stored in the compartment on the back of the  
5. Store the compressor hose and tire fitting in storage compartment.  
unit — see page 2) to the Deflator Port inside the Air Panel.  
3. Attach the appropriate nozzle to the free end of the Inflator/Deflator Hose.  
4. Slide the Air Compressor/Inflator Switch to INFLATOR.  
Inflating Products Without a Valve Stem Using the Compressor  
Inflation of other items requires use of one of the adapters (nozzles).  
5. When product is fully deflated, turn the Air Compressor/Inflator Switch to OFF,  
1. Insert appropriate adapter (e.g. needle) into the connector (chuck) on the Air  
remove hose from valve and close the valve.  
Compressor Hose and close thumb latch.  
2. Insert adapter (e.g. needle) into item to inflate.  
3. Slide Air Compressor/Inflator Switch to COMPRESSOR.  
CARE AND MAINTENANCE  
CAUTION  
If the cord, wires, or cables become damaged, return the entire unit  
to Power On Board immediately for service/repair.  
4. Refer to the following table for approximate filling pressure and time. Small items  
such as volleyballs, footballs, etc. inflate very rapidly.  
5. Monitor the pressure gauge. When desired pressure is reached, slide the Air  
Compressor/Inflator Switch to OFF; open thumb latch and remove connector  
from valve stem.  
Replacement Parts  
For replacement parts (bulbs, batteries, fuses, adapters, hoses, etc.), contact Customer  
Service, toll-free, at at (954) 584-4446 or toll free at (866) 584-5504.  
6. Remove adapter from item and store properly.  
Typical Inflation Times  
Battery Replacement/Disposal  
It is recommended that the unit be returned to Customer Service  
for battery replacement.  
This unit contains a maintenance-free, non-spillable, sealed lead-  
acid battery. This battery is fully recyclable and should be  
accepted at any location that accepts common automotive  
batteries. Examples of places that accept these batteries are:  
county or municipal recycling drop-off centers, scrap metal  
dealers and retailers who sell automotive replacement lead acid  
batteries.  
Inflation pressure (psi)  
Approx. Filling time  
Vehicle and trailer tires  
155/80R 13"  
26  
30  
30  
42  
2.5 min.  
4.5 min.  
6.5 min.  
16 min.  
185/70R 14"  
235/75R 16"  
235/70R 17"  
Bicycle tires  
27" X 1" (racing)  
90  
40 sec.  
Football  
Basketball  
Volleyball  
13  
10  
5
24 sec.  
20 sec.  
6 sec.  
WARNINGS  
WARNING  
Do not dispose of the battery in fire, as this may result in an explosion.  
Always follow tire manufacturers recommendations for pressure on  
Before disposing of the battery, protect exposed terminals with  
heavy-duty electrical tape to prevent shorting (shorting can result in  
injury or fire).  
item to be inflated.  
Note: Thermo-protection device shuts down the unit when the unit overheats and  
restarts once the unit has reached a safe operating temperature (usually 15  
minutes).  
Do not expose battery to fire or intense heat, as it may explode.  
Fuse Replacement (DC Accessory Adapter)  
Using the Inflator/Deflator  
Inflating  
1. Remove plug from accessory outlet. Remove the gold cap by turning counter-  
clockwise and lifting off.  
1. Locate the inflation valve on your product and open it.  
2. Remove center pin and spring. Remove fuse.  
3. Replace fuse with same type and size fuse (8 amp).  
4. Replace center pin and spring inside plug.  
5. Replace gold cap by turning clockwise.  
2. Fasten the Inflator/Deflator Hose (stored in the compartment on the back of the  
unit — see page 2) to the Inflator Port inside the Air Panel.  
3. Attach the appropriate nozzle to the free end of the Inflator/Deflator Hose.  
4. Slide the Air Compressor/Inflator Switch to INFLATOR.  
5. When product is fully inflated, turn the Air Compressor/Inflator Switch to OFF,  
remove hose from valve and close the valve.  
 
8
9
SPECIFICATIONS  
12 Volt DC Specifications  
Battery:  
12 volt DC rechargeable, maintenance-free  
Internal Battery Type:  
Sealed, AGM lead-acid  
Internal Battery  
Capacity:  
12 volt, 19Ah/20 hour rate  
Light Emitting Diode (LED)  
Area Light :  
Jumper Cables:  
Heavy duty welding cable  
with 450 amp clamps  
Accessory Outlet  
Protection:  
Self-resetting overload protection  
DC Charging Adapter: 12 volt DC  
AC Power Specifications  
Output Power:  
Continuous — 400 watts  
Output Voltage:  
120 VAC RMS  
60 Hz 4 Hz  
Modified sine wave  
Yes  
Output Frequency:  
Output Waveform:  
Overheat Protection:  
Overload Protection:  
Yes  
Output Short Circuit  
Protection:  
Yes  
Tire Inflator Specifications  
Maximum Pressure:  
120 PSI  
Battery Charger Specifications  
Input:  
120 volt AC, 60 Hz  
Rapid Charging  
Current:  
12 volt DC 1000mA  
 
10  
11  

Teac Car Stereo System CD P140 User Manual
Toshiba Projector MP8640 User Manual
Toshiba Projector TDP T98 User Manual
Triax Satellite Radio SR 110 User Manual
Uniden Cordless Telephone EXP 2900 User Manual
Uniden Portable Radio uh078sx User Manual
UTStarcom Cell Phone CDM 105 User Manual
Velodyne Acoustics Speaker HGS 15X THX User Manual
ViewSonic Computer Monitor VX922 User Manual
Vinotemp Refrigerator VT12TEDS2Z User Manual